Repeated Timing Jitter Measurement Summary
======================================================================

Bias Voltage: 16.00 V
Trigger Voltage: -0.430 V
Number of measurements: 10
Acquisition time per measurement: 10.0 s

Individual Measurements:
----------------------------------------------------------------------
Run	Peak_1_FWHM(ps)	Peak_2_FWHM(ps)	Countrate(cps)
1	42.52	42.39	356431.8
2	42.93	42.58	357418.5
3	42.36	42.53	357676.6
4	42.42	42.07	358291.6
5	41.59	42.06	357325.8
6	42.05	42.13	357612.4
7	42.13	42.72	357031.9
8	41.75	41.54	357842.4
9	42.38	42.21	357202.9
10	42.40	42.39	357998.1

======================================================================
Statistics:
----------------------------------------------------------------------
Peak 1 Average FWHM: 42.25  0.39 ps
Peak 2 Average FWHM: 42.26  0.34 ps
Average Countrate: 357483.2  529.0 cps