Filename: fig2.csv Description: Data showing conversion efficiency for several beam sizes Data: Row 1: pump power for 0.88 mm beam size (x-axis, unit: W) Row 2: pump power for 1.05 mm beam size (x-axis, unit: W) Row 3: pump power for 3.50 mm beam size (x-axis, unit: W) Row 4: efficiency for 0.88 mm beam size (y-axis, unit: %) Row 5: efficiency for 1.05 mm beam size (y-axis, unit: %) Row 6: efficiency for 3.50 mm beam size (y-axis, unit: %) Filename: fig5.csv Description: Data showing conversion efficiency with cooled vs. uncooled GaP crystal Data: Row 1: cooled efficiency (y-axis, unit: %) Row 2: uncooled efficiency (y-axis, unit: %) Row 3: pump power (x-axis, unit: W) Filename: fig7.csv Description: Raw data of THz-TDS traces captured under cooled and uncooled conditions Data: Row 1: time for cooled trace (x-axis, unit: ps) Row 2: signal for cooled trace (y-axis, unit: V) Row 3: standard deviation for cooled trace (unit: V) Row 4: time for uncooled trace (x-axis, unit: ps) Row 5: signal for uncooled trace (y-axis, unit: V) Row 6: standard deviation for uncooled trace (unit: V) Filename: fig8_fd.csv Description: Frequency-domain data from FROG scans of compressed 55 fs probe pulse Data: Col 1: frequency (x-axis) Col 2: Amplitude (y-axis, unit: a.u.) Col 3: Phase (y-axis, unit: radians) Filename: fig8_td.csv Description: Time-domain data from FROG scans of compressed 55 fs probe pulse Data: Col 1: time (x-axis, unit: fs) Col 2: Amplitude (y-axis, unit: a.u.) Col 3: Phase (y-axis, unit: radians) Filename: fig9_experimental_data.csv Description: Experimental spectral data of THz traces taken with uncompressed (245 fs) and compressed (55 fs) probe pulses. Data: Row 1: frequency for compressed probe scan FFT (x-axis, unit: THz) Row 2: power spectrum values for compressed probe scan FFT (y-axis, unit: a.u.) Row 3: frequency for uncompressed probe scan FFT (x-axis, unit: THz) Row 4: power spectrum values for uncompressed probe scan FFT (y-axis: unit: a.u.) Filename: fig9_simulation_data.csv Description: Simulation data for the simulation of THz detection with uncompressed (245 fs) and compressed (55 fs) probe pulses. Data: Row 1: frequency (x-axis; unit: Hz) Row 2: Detected THz spectrum, uncompressed probe (y-axis; unit: a.u.) Row 3: Detected THz spectrum, compressed probe (y-axis; unit: a.u.) Filename: fig9_TDS.csv Description: Raw data of THz-TDS traces captured with compressed and uncompressed probes Data: Row 1: signal for uncompressed probe trace (y-axis, unit: V) Row 2: time for uncompressed probe trace (x-axis, unit: ps) Row 3: signal for compressed probe trace (y-axis, unit: V) Row 4: time for compressed probe trace (x-axis, unit: ps) Filename: cooled.png Description: Image of pump beam profile after propagation through cooled crystal at 25 W pump power Filename: uncooled.png Description: Image of pump beam profile after propagation through uncooled crystal at 25 W pump power Filename: cooled.tiff Description: Thermal image of cooled crystal after 7 minutes of exposure to 25 W pump beam Filename: uncooled.tiff Description: Thermal image of uncooled crystal after 7 minutes of exposure to 25 W pump beam